Every email you send, every video stream you watch, every financial transaction you execute—at some point in its journey, your data travels through a physical wire. While wireless technologies capture public attention with their convenience, wired transmission remains the backbone of global communication infrastructure. The submarine cables crossing ocean floors, the fiber optic lines threading through metropolitan areas, and the copper cables connecting devices to switches—these physical pathways carry over 95% of international internet traffic.
Understanding wired transmission isn't merely academic. Whether you're designing a data center, troubleshooting network performance, selecting cabling for an office build-out, or architecting systems that depend on specific bandwidth guarantees, the principles of guided media directly impact your engineering decisions.
By the end of this page, you will understand the fundamental physics of wired transmission, know why physical cables remain critical to modern networking, and be able to reason about how electrical and optical signals traverse conductors. This forms the foundation for understanding specific cable types covered in subsequent modules.
Wired transmission, also known as guided transmission or bounded transmission, refers to the propagation of electromagnetic signals through a physical medium that constrains and directs the signal along a predetermined path. Unlike wireless (unguided) transmission where signals radiate freely through space, wired transmission confines signals within a conductor—be it copper wire, coaxial cable, or optical fiber.
This distinction has profound implications for network design:
| Characteristic | Wired (Guided) | Wireless (Unguided) |
|---|---|---|
| Signal Path | Constrained within conductor | Radiates through free space |
| Signal Attenuation | Predictable, distance-dependent | Complex, affected by obstacles, weather, interference |
| Bandwidth Potential | Very high (especially fiber) | Limited by spectrum allocation |
| Security | Physically isolable, harder to intercept | Broadcasts to all receivers in range |
| Installation | Requires physical infrastructure | Minimal infrastructure after towers/access points |
| Reliability | Extremely high when properly installed | Variable, environmental factors |
| Latency | Minimal, deterministic | Higher, variable due to contention |
| Cost Model | High upfront, low operational | Lower upfront, ongoing spectrum costs |
The term 'guided media' directly reflects the physical reality: the conductor guides the electromagnetic wave along its length. Just as a river channel guides water flow, a copper cable guides electrical signals and an optical fiber guides light. This guidance is what enables predictable, reliable signal delivery over long distances.
The three primary types of guided media are:
Each type leverages different physical phenomena to achieve signal transmission, but all share the fundamental characteristic of physically guiding signals along a defined path.
To truly understand wired transmission, we must examine the underlying physics. All wired communication relies on electromagnetic phenomena—either the propagation of electrical signals through conductors or the propagation of light through optical media.
When we transmit data through copper cables, we're not moving electrons from sender to receiver. Instead, we're propagating an electromagnetic wave guided by the conductor. Here's what actually happens:
Think of a Mexican wave in a stadium. Each person (electron) moves only slightly up and down, but the wave pattern travels around the stadium at high speed. Similarly, electrons barely move, but the electromagnetic field pattern they create propagates rapidly along the conductor. The wire acts as a waveguide constraining this propagation.
Impedance — Every transmission line has a characteristic impedance (measured in ohms) determined by its physical properties. For standard Ethernet cables, this is 100Ω. Mismatched impedance causes signal reflections that corrupt data.
Capacitance — Conductors separated by insulation form a capacitor. Cable capacitance affects how quickly voltage levels can change, limiting maximum data rate. Lower capacitance enables higher frequencies.
Inductance — Current flow creates a magnetic field that opposes changes in current. Cable inductance interacts with capacitance to determine propagation speed and signal behavior.
Resistance — All conductors have resistance that converts some signal energy to heat. Lower resistance means less signal loss, which is why thicker cables support longer runs.
Skin Effect — At high frequencies, current concentrates near the conductor's surface. This effectively increases resistance at higher frequencies, causing frequency-dependent attenuation.
| Property | Physical Basis | Networking Impact |
|---|---|---|
| Characteristic Impedance | Ratio of voltage to current in propagating wave | Must match between cable and equipment; mismatch causes reflection and data errors |
| Propagation Velocity | Speed of electromagnetic wave in medium | Determines minimum cable length timing; affects protocol design |
| Attenuation per Unit Length | Energy loss due to resistance, dielectric | Limits maximum cable run distance |
| Bandwidth | Frequency range with acceptable attenuation | Determines maximum data rate capacity |
| Crosstalk Coupling | Electromagnetic interference between conductor pairs | Limits signal-to-noise ratio and effective data rate |
While copper cables use electrical signals, fiber optic cables use light as the transmission medium. This fundamental difference enables dramatically higher bandwidths and longer transmission distances.
Optical fiber transmission relies on total internal reflection—a phenomenon where light striking a boundary between two materials at a shallow angle is completely reflected back into the first material.
Fiber optic technology offers compelling advantages over electrical transmission:
Enormous Bandwidth — Light frequencies are measured in hundreds of terahertz, enabling data rates impossible with electrical signals. A single fiber strand can carry multiple wavelengths (colors) simultaneously, each bearing independent data streams.
Minimal Attenuation — Modern single-mode fiber loses only about 0.2 dB/km at 1550nm wavelength. Signals can travel 100+ km without amplification. Compare this to copper, where losses of 20+ dB/100m are typical.
Electromagnetic Immunity — Light is immune to electrical interference. Fiber cables can run alongside high-voltage power lines, through electrically noisy industrial environments, or across lightning-prone areas without signal degradation.
Security — Fiber is extremely difficult to tap without detection. Unlike copper, there's no electromagnetic radiation to intercept. Physical tapping causes measurable signal loss.
Weight and Size — Fiber cables are dramatically lighter and smaller than copper cables for equivalent capacity. A single fiber strand thinner than a human hair can carry as much data as thousands of copper pairs.
Despite its advantages, fiber has tradeoffs: higher cost for connectors and equipment, requirement for specialized installation tools, fragility compared to copper (though modern cables are quite robust), and the need for electrical power at endpoints (fiber doesn't carry power like Power-over-Ethernet). These factors explain why copper remains prevalent in many applications.
Digital data must be converted to physical signals for transmission. This conversion—called encoding or modulation—determines how bits are represented on the wire.
In copper cables, data is represented by voltage levels or transitions:
| Signaling Scheme | How It Works | Application |
|---|---|---|
| Single-ended | Voltage measured against ground reference | Legacy RS-232, simple sensors |
| Differential | Voltage difference between two conductors | Ethernet, USB, RS-485—noise immunity |
| NRZ (Non-Return-to-Zero) | High voltage = 1, Low voltage = 0 | Basic serial communication |
| Manchester | Transition in middle of bit period | 10BASE-T Ethernet—self-clocking |
| PAM-4 | Four voltage levels encode 2 bits per symbol | High-speed Ethernet (2.5G+)—bandwidth efficiency |
Modern high-speed networks universally use differential signaling. Instead of measuring voltage relative to ground, the receiver measures the voltage difference between two conductors.
Why is this superior?
Common-Mode Rejection — External interference affects both conductors equally. Since the receiver only cares about the difference, common interference is canceled out. A 1V noise spike on both wires becomes 0V difference—invisible to the receiver.
Lower Voltage Requirements — Differential signaling can use smaller voltage swings while maintaining signal integrity, reducing power consumption and electromagnetic emissions.
Controlled Impedance — The balanced nature of differential pairs enables precise impedance control, reducing reflections at high frequencies.
This is precisely why twisted pair cables twist the conductors together. Twisting ensures that both wires in a pair are equally exposed to any external interference source, maximizing common-mode rejection. The more twists per inch, the better the noise immunity—which is why higher category cables have tighter twist rates.
In fiber optics, data representation is simpler conceptually but sophisticated in implementation:
On-Off Keying (OOK) — The simplest scheme: light on = 1, light off = 0. Used in traditional fiber links up to 10 Gbps.
PAM-4 Optical — Four intensity levels encode 2 bits per symbol. Used in 100G and 400G links to double throughput within bandwidth constraints.
Coherent Modulation — Modulates phase, amplitude, and polarization of light. Enables extreme data rates (400G+) and long-haul transmission. Requires sophisticated digital signal processing.
Wavelength Division Multiplexing (WDM) — Multiple wavelengths (colors) of light travel through the same fiber simultaneously. Each wavelength carries independent data. Dense WDM systems pack 80+ wavelengths into a single fiber, achieving aggregate rates of terabits per second.
Real-world transmission media are imperfect. Signals degrade as they travel, and understanding these impairments is essential for designing reliable networks.
Attenuation is the reduction in signal strength as it travels through the medium. All transmission media exhibit attenuation—it's a question of degree.
Distortion occurs when different frequency components of a signal travel at different speeds, causing the signal to spread out over time. This limits how fast bits can be transmitted before they blur together.
In Copper:
In Fiber:
Noise is unwanted energy that corrupts signals. Sources include:
Thermal Noise — Random electron motion in conductors (present in all electrical systems, cannot be eliminated)
Electromagnetic Interference (EMI) — External sources like motors, power lines, radio transmitters. Shielding and differential signaling mitigate EMI.
Crosstalk — Signals from adjacent conductor pairs coupling electromagnetically. Twisting and shielding reduce crosstalk.
Quantization Noise — In digital systems, the rounding errors from analog-to-digital conversion.
Shot Noise — In optical systems, the random arrival times of photons create statistical variations in detected signal.
SNR quantifies signal quality: the ratio of signal power to noise power, measured in decibels (dB). Higher SNR enables higher data rates and lower error rates. Every transmission system has a maximum achievable data rate determined by its bandwidth and SNR—this is the Shannon limit, the theoretical maximum capacity of any communication channel.
Despite the convenience of wireless technology, wired transmission continues to dominate critical network infrastructure. Understanding why helps clarify when to choose wired solutions.
Wired networks are deterministic in ways wireless networks cannot be. Signal propagation follows predictable physics with minimal environmental variability. This enables:
Capacity per Dollar — For high-bandwidth requirements, wired infrastructure costs far less than equivalent wireless capacity. A single 400G fiber link costs less than the radio spectrum and equipment for much lower aggregate wireless capacity.
Operational Costs — Once installed, copper and fiber have minimal operational cost. No spectrum licenses, no RF engineering, minimal maintenance.
Longevity — Physical cables last decades. Fiber installed in the 1990s still carries modern traffic. The cable plant outlives multiple generations of endpoints.
For sensitive environments, wired networks provide physical security impossible with wireless:
Modern networks are hybrid. Wireless provides user mobility and convenience at the edge. Wired infrastructure provides the backbone capacity, reliability, and determinism that wireless depends upon. Your wireless access point connects to a wired switch. That switch connects to a wired router. And that router connects to wired connections that ultimately reach fiber optic cables crossing continents.
Beyond physics, wired transmission involves practical engineering realities that influence design decisions.
Every cable type has maximum run length based on signal attenuation and timing constraints:
100BASE-TX / 1000BASE-T Ethernet — Maximum 100 meters over Cat5e/Cat6 twisted pair 10GBASE-T — Maximum 100 meters over Cat6a; 55 meters over Cat6 Multimode Fiber (1G) — Up to 550 meters for OM4 Single-mode Fiber (1G) — 10+ kilometers typically, 80+ km with appropriate optics
These limits aren't arbitrary—they're derived from the physics of signal attenuation, crosstalk, and timing.
A cable's theoretical specifications are only achieved with proper installation:
A $2 cable terminated incorrectly costs far more than a $5 cable done right. Intermittent connectivity issues, reduced link speeds, and difficult-to-diagnose problems all trace back to installation. Budget for certification testing on any permanent infrastructure installation.
Plenum Spaces — Cables running through air-handling spaces must use plenum-rated jackets that produce less toxic smoke in fires. Required by building codes.
Outdoor Installations — UV exposure, temperature extremes, and moisture require specifically rated cables. Direct burial cables include additional protection.
Industrial Environments — EMI from motors and equipment may require shielded cables or fiber. Chemical exposure requires appropriate jacket materials.
Temperature Ratings — Cable specifications assume operating temperature ranges. Data centers with precision cooling can use standard cables; outdoor deployments need extended temperature ratings.
We've established the foundational concepts of wired transmission that underpin all subsequent material in this chapter. Let's consolidate the key points:
What's Next:
The next page explores signal propagation in detail—how signals actually travel through different media, the physics of wave propagation, and how propagation characteristics influence network design. We'll examine propagation velocity, delay calculations, and the timing constraints that shape network protocols.
You now understand the fundamental physics and engineering of wired transmission. This foundation enables you to reason about cable selection, performance expectations, and design tradeoffs. Next, we'll dive deeper into how signals propagate through these media and the implications for network design.